- Contact Person : Ms. Zheng Sonya
- Company Name : Shenzhen Ricso Technology Co., Ltd.
- Tel : 0086-0755-33225612
- Fax : 0086-0755-33225615
- Address : Guangdong,Shenzhen,303#, Building 2, Creative Technology Science Park, Taoyuan Street, Nanshan, Shenzhen, China
- Country/Region : China
- Zip : 518055
coagulation analyzer
Coagulation Analyzer
Model:BN1000
Feature
Special testing cup location system, adding sample bracket
Advanced optical light matching system ensure precision result
Optional PT Derived method for testing fibrinogen, decease the dosage of reagent
Top quality thermostat, precision 37°C±0.3°C
Dispense precision: CV‹2%
Memory for 10,000 testing results
Internal thermal-sensitive printer
Electronically-linked pipette
Perform all routine tests such as PT, APTT, TT, Fibrinogen and clotting factors
RS232 interface, PC connecting
Specification
Testing channel:1 channel
Sample incubation block:5
Reagent incubation block:2
Software timer:1
Memory:10000 test result
Test wavelength: 470nm
Temp control precision: 37±0.3°C
Reagent consume:20uL-40uL
Notation of Result: S,%,PTR, INR, g/L
Printer: build-in micro-printer, 58mm paper width
Data entry: keyboard
Operation language: English
Power supply: 220VAC±15% or 110VAC±15% 50-60 Hz 80w
Temperature:10°C-30°C,wet≤80%
Dimensions:270mm(L)×270mm(W) ×150mm(H)
Weight:6 kg
Usual test list
Prothrombin PT
Activated partial thromboplastin time APTT
Thrombin Time TT
Fibrinogen FIB, RT, VT, VIII, IX, XI, XII, II, V, VII, X, PS, PC, Xa, etc.
What difference among these types?
BN1000 | BN2000 | BN4000 | ||
Usual test list | Prothrombin PT Activated partial thromboplastin time APPTT Thrombin Time TT Fibrinogen FIB, RT, VT, VIII, IX, XI, XII, II, V, VII, X, PS, PC, Xa, etc. | |||
Testing channel number | 1 | 2 channel,2 different parameters analysis in the same time | 4 channel,4 different parameters analysis in the same time | |
Sample incubation block | 5 | 16 | 24 | |
Reagent incubation block | 2 | 4 | 6 | |
Software timer | 1 | 2 | 4 | |
Memory | 10,000 test result | |||
Test wavelength | 470nm | |||
Temp contrl precision | 37°C±0.3°C | |||
Sample consume | 20uL-40uL | |||
Reagent consume | 20uL-40uL | |||
Coincidence indicator | ≤3% | |||
Notation of Result | S,%,PTR, INR, g/L | |||
Printer | build-in micro-printer, 58mm paper width | |||
Work environment | 10 -30°C,wet<80% | |||
Power supply | 220VAC±15% or 110VAC±15% 50-60 Hz 80W | |||
Dimensions | 27cm*27cm*12cm | 40cm*32cm*14cm | ||
Weight | 6 kg |